Section 4106. �Plastic Film and Insulating Covers for Curing Concrete
A.��� Comply with the following:
1.���� Tough, pliable, moisture proof, and durable
2.���� Material will retain its moisture proof properties while it is in place on the surface of the concrete.
3.���� White pigmented material that is opaque.
4.���� No less than 0.85 mils (21 �m) thick.
5.���� No less than 70% daylight reflectance relative to magnesium oxide when tested according to ASTM E 1347.
B.��� If the thickness of plastic film is less than 3.4 mils (85 �m), do not use it more than once for curing concrete.
4106.02���� INSULATING COVERS.
Comply with the following:
A.��� Cellulosic fiber sheeting with a nominal 3/4 inch (20 mm) thickness.
B.��� Similar to sheeting specified in ASTM C 208.