Section 4105. �Liquid Curing Compounds
4105.01���� general requirements.
Comply with AASHTO M 148 and the following requirements.
Use compounds of a consistency that they can be readily applied by spraying to a uniform coating at a material temperature above 40�F (4�C).
4105.03���� MOISTURE RETENTION.
White pigmented liquid curing compounds, when tested in accordance with ASTM C 156 using an application rate of 200 square feet per gallon (5 m2/L) shall restrict the loss of water to not more than 0.20 kg/m2 in 24 hours or 0.40 kg/m2 in 72 hours.
Use liquid curing compounds that:
� Dry to the touch in no more than 4 hours, and
� Do not track off the concrete when walked upon after 12 hours.
4105.05���� WHITE PIGMENTED COMPOUNDS.
A.��� Use compounds consisting of finely ground white pigment and vehicle, ready mixed for use without alteration.
B.��� Ensure the pigment does not:
� Settle excessively or cake in the container, and
� Thicken in storage to cause a change in consistency which may result in a nonuniform spray.
C.��� Use a compound that after being sprayed on a test slab and drying has an apparent daylight reflectance no less than 60% relative to magnesium oxide.
D.��� Agitate the compound just prior to it being removed from the container. Agitate it continuously during application.
4105.06���� DARK COLORED COMPOUNDS.
Use asphalt emulsion or asphalt cut back with a volatile solvent. Use a mixture containing no less than 50.0% asphalt. Use an application rate of no less than 0.08 gallon per square yard (0.36 L/m2) (12.5 square yards per gallon (2.8 m2/L)).
Apply the following in lieu of other requirements of this section:
A.��� Use clear liquid membrane curing compounds complying with the requirements of AASHTO M 148, Type 1-D, Class A. Use only one type of compound on a structure. Do not use different compounds on the same structure.
B.��� Inspection and acceptance of clear compounds for curing will be according to Materials I.M. 405.07.
A.��� Approvals of individual lots of curing compound are valid for the year in which the compound is manufactured.
B.��� Lots of 5 barrels (1000 L) or more of white pigmented compound which have been carried over the winter will be retested if stored in a heated warehouse.
C.��� Do not use carryover lots of white pigmented compound less than 5 barrels (1000 L).
D.��� Do not use carryover lots of curing compounds which have been frozen.